Web: | mayocliniclabs.com |
---|---|
Email: | mcl@mayo.edu |
Telephone: | 800-533-1710 |
International: | +1 855-379-3115 |
Values are valid only on day of printing. |
This Anti-Synthetase Profile is comprised of Anti-Jo-1 Ab, Anti-PL-7 Ab, Anti-PL-12 Ab, Anti-EJ Ab and Anti-OJ Ab. Anti-synthetase syndrome is an autoimmune disease characterized by interstitial lung disease (ILD), non-erosive arthritis, myositis, Raynaud’s phenomenon, unexplained fever and/or mechanic’s hands.
Anti-PL-7 Ab, Anti-PL-12 Ab, Anti-EJ Ab, Anti-OJ Ab:
Reference Range: Negative
Interpretation for:
Anti-Jo-1 Ab:
Reference Range: <20
Negative: <20 units
Weak Positive: 20-39 units
Moderate Positive: 40-80 units
Strong Positive: >80 units