Test Catalog

Test Id : MAMLF

MAML2 (11q21) Rearrangement, Mucoepidermoid Carcinoma (MEC), FISH, Tissue

Useful For
Suggests clinical disorders or settings where the test may be helpful

Supporting a diagnosis of mucoepidermoid carcinoma

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
_PBCT Probe, +2 No, (Bill Only) No
_PADD Probe, +1 No, (Bill Only) No
_PB02 Probe, +2 No, (Bill Only) No
_PB03 Probe, +3 No, (Bill Only) No
_IL25 Interphases, <25 No, (Bill Only) No
_I099 Interphases, 25-99 No, (Bill Only) No
_I300 Interphases, >=100 No, (Bill Only) No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

This test does not include a pathology consultation. If a pathology consultation is requested, PATHC / Pathology Consultation should be ordered and the appropriate FISH test will be ordered and performed at an additional charge. 

.

This test includes a charge for application of the first probe set (2 FISH probes) and professional interpretation of results.

 

Additional charges will be incurred for all reflex probes performed. Analysis charges will be incurred based on the number of cells analyzed per probe set. If no cells are available for analysis, no analysis charges will be incurred.

Method Name
A short description of the method used to perform the test

Fluorescence In Situ Hybridization (FISH)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

MAML2 (11q21), FISH, Ts

Aliases
Lists additional common names for a test, as an aid in searching

Salivary gland tumor

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

This test does not include a pathology consultation. If a pathology consultation is requested, PATHC / Pathology Consultation should be ordered and the appropriate FISH test will be ordered and performed at an additional charge. 

.

This test includes a charge for application of the first probe set (2 FISH probes) and professional interpretation of results.

 

Additional charges will be incurred for all reflex probes performed. Analysis charges will be incurred based on the number of cells analyzed per probe set. If no cells are available for analysis, no analysis charges will be incurred.

Specimen Type
Describes the specimen type validated for testing

Tissue

Necessary Information

1. A pathology report is required in order for testing to be performed. Acceptable pathology reports include working drafts, preliminary pathology or surgical pathology reports.

2. A reason for testing must be provided. If this information is not provided, an appropriate indication for testing may be entered by Mayo Clinic Laboratories.

ORDER QUESTIONS AND ANSWERS

Question ID Description Answers
CG930 Reason for Referral

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Submit only 1 of the following specimens:

 

Specimen Type: Tissue

Preferred: Tissue block

Container/Tube: Formalin-fixed, paraffin-embedded (FFPE) tumor tissue block.

Collection Instructions: Blocks prepared with alternative fixation methods may be acceptable; provide fixation method used.

 

Acceptable: Slides

Specimen Volume: Four consecutive, unstained, 5 micron-thick sections placed on positively charged slides and 1 hematoxylin and eosin-stained slide.

Forms

If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

Two consecutive, unstained, 5-micron-thick sections placed on positively charged slides, and 1 hematoxylin and eosin-stained slide.

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Tissue Ambient (preferred)
Refrigerated

Useful For
Suggests clinical disorders or settings where the test may be helpful

Supporting a diagnosis of mucoepidermoid carcinoma

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

This test does not include a pathology consultation. If a pathology consultation is requested, PATHC / Pathology Consultation should be ordered and the appropriate FISH test will be ordered and performed at an additional charge. 

.

This test includes a charge for application of the first probe set (2 FISH probes) and professional interpretation of results.

 

Additional charges will be incurred for all reflex probes performed. Analysis charges will be incurred based on the number of cells analyzed per probe set. If no cells are available for analysis, no analysis charges will be incurred.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Mucoepidermoid carcinoma (MEC) is the most common malignant salivary gland neoplasm, representing over 30% of all malignant salivary gland tumors. The diagnosis of MEC can be quite challenging due to the degree of histologic overlap with other glandular, clear cell, or oncocytic salivary gland tumors. MAML2 rearrangements are detectable in 80% to 85% of MEC, but not in morphologic mimics such as oncocytic cystadenoma, Warthin tumor, oncocytoma, oncocytic carcinoma, acinic cell carcinoma, and metastatic renal cell carcinoma.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

An interpretive report will be provided.

Interpretation
Provides information to assist in interpretation of the test results

A neoplastic clone is detected when the percent of cells with an abnormality exceeds the normal cutoff for the MAML2 probe.

 

A positive result is consistent with a diagnosis of mucoepidermoid carcinoma (MEC).

 

A negative result suggests no rearrangement of the MAML2 gene region at 11q21. However, this result does not exclude the diagnosis of MEC.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

This test is not approved by the US Food and Drug Administration and it is best used as an adjunct to existing clinical and pathologic information.

 

Fixatives other than formalin (eg Prefer, Bouin) may not be successful for FISH assays, however nonformalin-fixed samples will not be rejected.

 

Paraffin-embedded tissues that have been decalcified are generally unsuccessful for FISH analysis. The pathologist reviewing the hematoxylin and eosin-stained slide may find it necessary to cancel testing.

Supportive Data

FISH analysis was performed on 28 mucoepidermoid carcinoma (MEC) formalin-fixed paraffin-embedded tissue samples and 51 control specimens. The normal controls were used to generate a normal cutoff for this assay. A rearrangement of MAML2 was identified in 26 of 28 (93%) MEC cases.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Stewart FW, Foote FW, Becker WF: Mucoepidermoid tumors of salivary glands. Ann Surg 1945;122:820-844

2. Spiro RH, Huvos AG, Berk R, Strong EW: Mucoepidermoid carcinoma of salivary gland origin. A clinicopathologic study of 367 cases. Am J Surg 1978;136:461-468

3. Seethala RR, Dacic S, Cieply K, et al: A reappraisal of the MECT1/MAML2 translocation in salivary mucoepidermoid carcinomas. Am J Surg Pathol 2010 Aug;34(8):1106-1121

4. Behboudi A, Enlund F, Winnes M, et al: Molecular classification of mucoepidermoid carcinomas-prognostic significance of the MECT1-MAML2 fusion oncogene. Genes Chromosomes Cancer 2006 May;45(5):470-481

Method Description
Describes how the test is performed and provides a method-specific reference

The test is performed using a laboratory-developed MAML2 (11q21) dual-color break-apart strategy probe (BAP). Formalin-fixed paraffin-embedded tissues are cut at 5 microns and mounted on positively charged glass slides. The selection of tissue and the identification of target areas on the hematoxylin and eosin (H and E)-stained slide is performed by a pathologist. Using the H and E-stained slide as a reference, target areas are etched with a diamond-tipped etcher on the back of the unstained slide to be assayed. The probe set is hybridized to the appropriate target areas and 2 technologists each analyze 50 interphase nuclei (100 total) with the results expressed as the percent of abnormal nuclei.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

7 to 10 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

Slides and H&E used for analysis are retained by the laboratory in accordance to CAP and NYS requirements. Client provided paraffin blocks and extra unstained slides (if provided) will be returned after testing is complete.

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

88271x2, 88291-DNA probe, each (first probe set), Interpretation and report

88271x2-DNA probe, each; each additional probe set (if appropriate)

88271x1-DNA probe, each; coverage for sets containing 3 probes (if appropriate)

88271x2-DNA probe, each; coverage for sets containing 4 probes (if appropriate)

88271x3-DNA probe, each; coverage for sets containing 5 probes (if appropriate)

88274 w/modifier 52-Interphase in situ hybridization, <25 cells, each probe set (if appropriate)

88274-Interphase in situ hybridization, 25 to 99 cells, each probe set (if appropriate)        

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
MAMLF MAML2 (11q21), FISH, Ts 74034-0
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
54689 Result Summary 50397-9
54692 Interpretation 69965-2
54691 Result 62356-1
54918 Specimen 31208-2
54694 Source 31208-2
54695 Tissue ID 80398-1
54696 Released By 18771-6
CG930 Reason For Referral 42349-1
55136 Method 85069-3
55137 Additional Information 48767-8
53394 Disclaimer 62364-5

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports