Test Catalog

Test Id : COKEX

Cocaine and Metabolite Confirmation, Chain of Custody, Random, Urine

Useful For
Suggests clinical disorders or settings where the test may be helpful

Detecting and confirming drug abuse involving cocaine

 

Chain of custody is required whenever the results of testing could be used in a court of law. Its purpose is to protect the rights of the individual contributing the specimen by demonstrating that, at all times, it was under the control of personnel involved with testing the specimen; this control implies that the opportunity for specimen tampering would be limited.

 

This test is not intended for use in employment-related testing.

Additional Tests
Lists tests that are always performed, at an additional charge, with the initial tests.

Test Id Reporting Name Available Separately Always Performed
COCH Chain of Custody Processing No Yes
ADLTX Adulterants Survey, CoC, U Yes Yes

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

Adulterants testing will be performed on all chain-of-custody urine samples as per regulatory requirements.

Method Name
A short description of the method used to perform the test

COKEX: Immunoassay/Gas Chromatography Mass Spectrometry (GC-MS)

ADLTX: Spectrophotometry

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Cocaine and metabolite Conf, CoC, U

Aliases
Lists additional common names for a test, as an aid in searching

Benzoylecgonine (Cocaine Metabolite)

Cocaine

Cocaine Confirmation, QN, Urine

Coke (Cocaine)

Crack (Cocaine)

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

Adulterants testing will be performed on all chain-of-custody urine samples as per regulatory requirements.

Specimen Type
Describes the specimen type validated for testing

Urine

Ordering Guidance

This test is for situations that require the chain-of-custody process. For testing not requiring chain of custody, order COKEU / Cocaine and Metabolite Confirmation, Random, Urine.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Chain of Custody Kit (T282)

Container/Tube: Chain of custody kit containing the specimen containers, seals, and documentation required

Specimen Volume: 10 mL

Collection Instructions: Collect specimen in the container provided, seal, and submit with the associated documentation to satisfy the legal requirements for chain-of-custody testing.

Additional Information: Submitting less than 10 mL will compromise the ability to perform all necessary testing.

Forms

1. Chain of Custody Request is included in the Chain of Custody Kit (T282).

2. If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

5 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 14 days
Frozen 14 days
Ambient 72 hours

Useful For
Suggests clinical disorders or settings where the test may be helpful

Detecting and confirming drug abuse involving cocaine

 

Chain of custody is required whenever the results of testing could be used in a court of law. Its purpose is to protect the rights of the individual contributing the specimen by demonstrating that, at all times, it was under the control of personnel involved with testing the specimen; this control implies that the opportunity for specimen tampering would be limited.

 

This test is not intended for use in employment-related testing.

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

Adulterants testing will be performed on all chain-of-custody urine samples as per regulatory requirements.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Cocaine is a drug of current health concern because of its proliferation among recreational drug abusers.

 

Freebase and crack increase the potential for major cocaine toxicity. Cocaine use is declining across the nation according to the National Institute of Drug Abuse.

 

Increasingly, laboratory results are disputed or there are medical/legal overtones. Therefore, physicians are finding an increased need to confirm positive results before informing or confronting the patients.

 

Chain of custody is a record of the disposition of a specimen to document all personnel who collected, handled, and performed the analysis. When a specimen is submitted in this manner, analysis will be performed in such a way that it will withstand regular court scrutiny.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Negative

Positives are reported with a quantitative gas chromatography mass spectrometry result.

Cutoff concentrations:

 

IMMUNOASSAY SCREEN

<150 ng/mL

 

COCAINE BY GC-MS

<50 ng/mL

 

BENZOYLECGONINE BY GC-MS

<50 ng/mL

Interpretation
Provides information to assist in interpretation of the test results

Reports will specifically indicate the presence or absence of cocaine and benzoylecgonine.

 

The presence of cocaine, or its major metabolite, benzoylecgonine, indicates use within the past 4 days.

 

Cocaine has a 6-hour half-life, so it will be present in urine for 1 day after last use.

 

Benzoylecgonine has a half-life of 12 hours, so it will be detected in urine up to 72 hours after last use.

 

There is no correlation between concentration and pharmacologic or toxic effects.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

No significant cautionary statements

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Baselt RC, Cravey RH. Disposition of Toxic Drugs and Chemicals in Man. 3rd ed. Year Book Medical Publishers; 1989

2. Langman LJ, Bechtel LK, Holstege C. Clinical toxicology. In: Rifai N, Chiu RWK, Young I, Burnham CAD, Wittwer CT, eds. Tietz Textbook of Laboratory Medicine. 7th ed. Elsevier; 2023:chap 43

Method Description
Describes how the test is performed and provides a method-specific reference

Drug classes are initially screened by an immunoassay technique.

The cocaine assay is based on the kinetic interaction of microparticles in a solution as measured by changes in light transmission. In the absence of sample drug, soluble drug conjugates bind to antibody-bound microparticles, causing the formation of particle aggregates. As the aggregation reaction proceeds in the absence of sample drug, the absorbance increases. When a urine sample contains the drug in question, this drug competes with the drug derivative conjugate for microparticle-bound antibody. Antibody bound to sample drug is no longer available to promote particle aggregation, and subsequent particle lattice formation is inhibited. The presence of sample drug diminishes the increasing absorbance in proportion to the concentration of drug in the sample. Sample drug content is determined relative to the value obtained for a known cutoff concentration of drug.(Package insert: Cocaine. Roche Diagnostics; 03/2019)

 

To accommodate the need to confirm specifically the presence of cocaine in urine, Mayo Clinic Laboratories offers a single test to identify cocaine and its principal metabolite, benzoylecgonine, by using gas chromatography mass spectrometry.(Chinn DM, Crouch DJ, Peat MA, Finkle BS, Jennison TA. Gas chromatography-chemical ionization mass spectrometry of cocaine and its metabolites in biological fluids. J Anal Toxicol. 1980;4[1]:37-42; Rosado T, Gonçalves A, Margalho C, Barroso M, Gallardo E. Rapid analysis of cocaine and metabolites in urine using microextraction in packed sorbent and GC/MS. Anal Bioanal Chem. 2017;409(8):2051-2063. doi:10.1007/s00216-016-0152-2)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

2 to 5 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

80353

G0480 (if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
COKEX Cocaine and metabolite Conf, CoC, U 53747-2
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
2903 Cocaine Immunoassay Screen 42241-0
36162 Cocaine-by GC/MS 20519-5
36163 Benzoylecgonine-by GC/MS 16226-3
36164 Cocaine Interpretation 69050-3
36165 Chain of Custody 77202-0

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports