Test Catalog

Test Id : FFMTH

Meconium Methadone Screen with Reflex Confirmation

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
FMTHM Meconium Methadone Confirm No No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If screen is positive, then the Meconium Methadone Confirmation (FMTHM) will be performed at no additional charge.

Method Name
A short description of the method used to perform the test

Immunoassay (IA); Chromatography/with Mass Spectrometry

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Meconium Methadone Scr/Confirm

Aliases
Lists additional common names for a test, as an aid in searching

Methadone

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If screen is positive, then the Meconium Methadone Confirmation (FMTHM) will be performed at no additional charge.

Specimen Type
Describes the specimen type validated for testing

Meconium

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Container/Tube: Sterile collection container

Specimen Volume: 3 g

Collection Instructions: Collect specimen into the same sterile collection container until 3 g of meconium have been collected or until the first milk stool appears. When at least 3 g of meconium has been collected, tightly screw on the cap of the collection vial and send specimen ambient.

Note: Specimens from different voids may be pooled if necessary.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

1 g

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis NA
Lipemia NA
Icterus NA
Other NA

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Meconium Ambient (preferred) 14 days
Frozen 365 days
Refrigerated 14 days

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If screen is positive, then the Meconium Methadone Confirmation (FMTHM) will be performed at no additional charge.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Initial presumptive testing by  immunoassay at the following testing threshold:

Methadone:       50 ng/gm

 

Presumptive positive confirmed by definitive chromatography mass spectrometry (GC/MC or LC/MS-MS)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Sunday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 6 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Medtox Laboratories, Inc.

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

80307

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FFMTH Meconium Methadone Scr/Confirm 43595-8
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
Z5603 Methadone 43595-8

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports