Test Catalog

Test Id : MOLPS

Molybdenum, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Monitoring of parenteral nutrition

 

Monitoring metallic prosthetic implant wear

 

As an indicator of molybdenum cofactor deficiency

Method Name
A short description of the method used to perform the test

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Molybdenum, S

Aliases
Lists additional common names for a test, as an aid in searching

Mo (Molybdenum)

Molybdenum (Mo)

Specimen Type
Describes the specimen type validated for testing

Serum

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Supplies: Metal Free Specimen Vial (T173)

Collection Container/Tube: Plain, royal blue-top Vacutainer plastic trace element blood collection tube

Submission Container/Tube: 7-mL Mayo metal-free, screw-capped, polypropylene vial

Specimen Volume: 1.6 mL

Collection Instructions:

1. Allow specimen to clot for 30 minutes; then centrifuge the specimen to separate serum from the cellular fraction.

2. Remove the stopper. Carefully pour specimen into a Mayo metal-free, polypropylene vial, avoiding transfer of the cellular components of blood. Do not insert a pipet into the serum to accomplish transfer, and do not ream the specimen with a wooden stick to assist with serum transfer.

3. See Metals Analysis Specimen Collection and Transport for complete instructions.

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

0.4 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days METAL FREE
Ambient 14 days METAL FREE
Frozen 14 days METAL FREE

Useful For
Suggests clinical disorders or settings where the test may be helpful

Monitoring of parenteral nutrition

 

Monitoring metallic prosthetic implant wear

 

As an indicator of molybdenum cofactor deficiency

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Molybdenum is an essential trace element found in the daily diet. It is a cofactor for some enzymes important in nitrogen metabolism (aldehyde dehydrogenase, xanthine oxidase, nicotinamide adenine dinucleotide dehydrogenase). Due to the wide distribution of molybdenum in the environment and particularly in plant materials, molybdenum deficiency is rare in adults with normal, diverse diets. Typical molybdenum intake in most geographic locations is between 45 and 90 mcg/day. Urine is the primary source of excretion, though excesses are sometimes excreted by the biliary route.

 

Molybdenum deficiency associated with parenteral nutrition is indicated by symptoms such as stunted growth, reduced appetite, tachycardia, tachypnea, blindness, and coma. These symptoms can be corrected by introducing molybdenum supplementation. Molybdenum cofactor disease is a severe genetic disorder that is due to defective variants in the MOCS1, MOCS2, and GEPH genes.

 

Molybdenum toxicity is rare and usually related to molybdenum mining exposure; however, it has been observed in cases of intake above 400 mcg/day. Molybdenum interferes with copper uptake; molybdenum toxicity is predominantly due to copper deficiency (hypochromic anemia and neutropenia) and inhibition of xanthine oxidase (uric acid accumulation).

 

Serum molybdenum concentrations are likely to be increased above the reference range in patients with metallic joint prosthesis. Prosthetic devices produced by Depuy Company, Dow Corning, Howmedica, LCS (low contact stress), PCA (porous-coated anatomic), Osteonics, Richards Company, Tricon, and Whiteside are typically made of chromium, cobalt, and molybdenum. This list of products is incomplete, and these products change occasionally; see prosthesis product information for each device for composition details.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

0.3-2.0 ng/mL

Interpretation
Provides information to assist in interpretation of the test results

Prosthesis wear is known to result in increased circulating concentrations of metal ions.(1) Serum concentrations above 10 ng/mL in a patient with molybdenum-based implant suggest significant prosthesis wear. Increased serum trace element concentrations in the absence of corroborating clinical information do not independently predict prosthesis wear or failure.

 

Serum molybdenum levels below 0.3 ng/mL indicate potential deficiency.

 

Increased serum molybdenum may be seen in acute viral hepatitis, chronic active hepatitis, alcoholic liver disease, and other forms of liver inflammation.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

No significant cautionary statements

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP: Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop. 2006 Oct;77(5):697-705

2. Centers for Disease Control and Prevention: The Third National Report on Exposure to Environmental Chemicals (NHANES). NCEH Publication 05-0570. National Center for Environmental Health; July 2005. Available at www.jhsph.edu/research/centers-and-institutes/center-for-excellence-in-environmental-health-tracking/Third_Report.pdf

3. Yoshida M, Ota S, Fukunaga K, Nishivama T: Serum molybdenum concentration in healthy Japanese adults determined by inductively coupled plasma-mass spectrometry. J Trace Elem Med Biol. 2006;20(1):19-23

4. Reiss J, Johnson JL: Mutations in the molybdenum cofactor biosynthetic genes MOCS1, MOCS2, and GEPH. Hum Mutat. 2003 Jun;21(6):569-576

5. Roberts NB, Taylor A, Sodi R: Vitamins and trace elements. Rifai N, Horvath AR, Wittwer CT, eds: Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 6th ed. Elsevier; 2018:chap 37

Method Description
Describes how the test is performed and provides a method-specific reference

The metal of interest is analyzed by inductively coupled plasma mass spectrometry.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Wednesday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

2 to 8 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

83018

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
MOLPS Molybdenum, S 5698-6
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
89270 Molybdenum, S 5698-6

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports