Test Catalog

Test Id : FAEAB

Anti-Enterocyte Antibodies

Method Name
A short description of the method used to perform the test

Indirect Immunofluorescence

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Anti-Enterocyte Antibodies

Aliases
Lists additional common names for a test, as an aid in searching

Anti Goblet Cell Ab

Anti-Enterocyte

Specimen Type
Describes the specimen type validated for testing

Serum Red

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

REQUIRED Completed Anti-Enterocyte Antibody (AEA) Clinical form.

(Testing will not proceed without required form)

 

Specimen Type: Serum

Container/Tube: Red

Specimen volume: 1 mL

Collection Instructions: Collect blood in a red-top no additive tube and submit 1 mL of serum shipped frozen.

 

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Forms

If not ordering electronically, complete, print, and send Gastroenterology and Hepatology Test Request (T728) with the specimen

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

1 mL 

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis NA
Lipemia NA
Icterus NA
Other NA

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Red Frozen

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

IgG: Negative

IgA: Negative

IgM: Negative

 

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Batched

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

28 to 56 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Children's Hospital of Philadelphia

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

These tests were developed and their performance characteristics determined by the Pathology Department at The Children’s Hospital of Philadelphia. They have not been cleared or approved by the U.S. Food And Drug Administration.  The FDA has determined that such clearance or approval is not necessary. These tests are used for clinical purposes.  It should not be regarded as investigational or for research.  This Laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high complexity clinical laboratory testing.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

88346

88350 x 2

 

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FAEAB Anti-Enterocyte Antibodies Not Provided
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
Z1700 Anti-Enterocyte Antibodies Not Provided
Z1687 Dilution of Serum Not Provided
Z1688 IgG Not Provided
Z1689 IgA Not Provided
Z1690 IgM Not Provided
Z1691 Signed Not Provided

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports