Test Catalog

Test Id : FUNID

Culture Referred for Identification, Fungus

Useful For
Suggests clinical disorders or settings where the test may be helpful

Identification of pure isolates of filamentous fungi and yeast

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
D2F D2 Fungal Sequencing Identification No, (Bill Only) No
FUNA Fungal Ident Panel A No, (Bill Only) No
FUNB Fungal Ident Panel B No, (Bill Only) No
LCCI Ident Rapid PCR Coccidioides No, (Bill Only) No
LCHB Id, Histoplasma/Blastomyces PCR No, (Bill Only) No
RMALF Id MALDI-TOF Mass Spec Fungi No, (Bill Only) No
RMALY Id MALDI-TOF Mass Spec Yeast No, (Bill Only) No
LCCA Id, Candida auris Rapid PCR No, (Bill Only) No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

When this test is ordered, the reflex tests may be performed and charged. All fungal organisms submitted will be identified and billed as appropriate.

Method Name
A short description of the method used to perform the test

Macroscopic/Microscopic/D2 rDNA Gene Sequencing/Real-Time Polymerase Chain Reaction (rtPCR)/Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS)

Dimorphic Pathogen Identification Confirmation: D2 rDNA Gene Sequencing/rtPCR/MALDI-TOF MS

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Culture Referred for ID, Fungus

Aliases
Lists additional common names for a test, as an aid in searching

Dermatophytes

Fungal ID

Fungal Identification

Fungi

Fungi ID

Fungi Identification

Fungus

Fungus ID

Fungus Identification

Fungus Referred for Identification

Identification of Fungus

Identification of Yeast

Mold

Referral for Identification

Yeast ID

Yeast Identification

Yeast Referred for Identification

Identification of Candida

Identification of Fungi

Identification of Mold

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

When this test is ordered, the reflex tests may be performed and charged. All fungal organisms submitted will be identified and billed as appropriate.

Specimen Type
Describes the specimen type validated for testing

Varies

Shipping Instructions

1. See Infectious Specimen Shipping Guidelines in Special Instructions for shipping information.

2. Place specimen in a large infectious container (T146) and label as an etiologic agent/infectious substance, if appropriate.

Necessary Information

1. Specimen source is required.

2. Isolate description is required: Gram stain reaction, morphology, tests performed.

ORDER QUESTIONS AND ANSWERS

Question ID Description Answers
Q00M0024 Specimen Source (Required) and Isolate Description-Stain reaction, morphology, tests performed (Required)

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Specimen Type: Organism in pure culture

Supplies: Infectious Container, Large (T146)

Container/Tube:

Preferred: Sabouraud dextrose agar slant

Acceptable: Inhibitory mold agar slant

Specimen Volume: Isolated mold or yeast

Collection Instructions: Organism must be in pure culture, actively growing. Do not submit mixed cultures.

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Forms

If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Agar plate Reject
 

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
Refrigerated

Useful For
Suggests clinical disorders or settings where the test may be helpful

Identification of pure isolates of filamentous fungi and yeast

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

When this test is ordered, the reflex tests may be performed and charged. All fungal organisms submitted will be identified and billed as appropriate.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Organisms are referred for identification or to confirm an identification made elsewhere. This may provide helpful information regarding the significance of the organism, its role in the disease process, and its possible origin.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Not applicable

Interpretation
Provides information to assist in interpretation of the test results

Genus and species are reported on fungal isolates whenever possible.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

If the organism is received in mixed culture or contaminated, the report may be delayed or identification may not be possible.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

Ashbee HR: General approaches for direction detection and identification of fungi. In: Carroll KC, Pfaller MA, Landry ML, et al, eds. Manual of Clinical Microbiology. 12th ed. Vol 1. ASM Press; 2019:2035-2055

Method Description
Describes how the test is performed and provides a method-specific reference

Identification of fungi is based on colonial and microscopic morphology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry, laboratory-developed real-time polymerase chain reaction (PCR) assays and/or D2 rDNA gene sequencing, as applicable.(Babady NE, Buckwalter SP, Hall L, Le Febre KM, Binnicker MJ, Wengenack NL: Detection of Blastomyces dermatitidis and Histoplasma capsulatum from culture isolates and clinical specimens by use of real-time PCR. J Clin Microbiol. 2011 Sep;49[9]:3204-3208; Binnicker MJ, Buckwalter SP, Eisberner JJ, et al: Detection of Coccidioides species in clinical specimens by real-time PCR. J Clin Microbiol. 2007 Jan;45[1]:173-178; Dhiman N, Hall L, Wohlfiel SL, Buckwalter SP, Wengenack NL: Performance and cost analysis of matrix-assisted laser desorption ionization time of flight mass spectrometry for routine identification of yeast. J Clin Microbiol. 2011 Apr;49[4]:1614-1616; Hall L, Wohlfiel SL, Roberts GD: Experience with the MicroSeq D2 large-subunit ribosomal DNA sequencing kit for identification of filamentous fungi encountered in the clinical laboratory. J Clin Microbiol. 2004 Feb;42[2]:622-626; Theel ES, Schmidt BH, Hall L, et al: Formic acid-based direct, on-plate testing of yeast and Corynebacterium species by Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol. 2012 Sep;50[9]:3093-3095; Theel ES, Hall L, Mandrekar J, Wengenack NL: Dermatophyte identification using matrix-assisted laser desorption ionization-time of flight mass spectrometry. J Clin Microbiol. 2011 Dec;49[12]:4067-4071)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Saturday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

2 to 35 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

30 days after identification

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

87107-Culture, fungi, definitive identification

87106-Culture, fungi, definitive identification, each organism; yeast (if appropriate)

87106-Id MALDI-TOF Mass Spec Yeast (if appropriate)

87107-Id MALDI-TOF Mass Spec Fungi (if appropriate)

87107-Culture, fungi, definitive identification, each organism; mold (if appropriate)

87107-Fungal identification Panel A (if appropriate)

87107-Fungal identification Panel B (if appropriate)

87150-Identification rapid PCR coccidioides (if appropriate)

87150 x 2-Identification Histoplasma/Blastomyces, PCR (if appropriate)

87153-D2 fungal sequencing Identification (if appropriate)

87150-Id, Candida auris Rapid PCR (if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
FUNID Culture Referred for ID, Fungus 42804-5
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
FUNID Culture Referred for ID, Fungus 42804-5

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports