Test Id : MGLE

Myasthenia Gravis/Lambert-Eaton Myasthenic Syndrome Evaluation, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Confirming the autoimmune basis of a defect in neuromuscular transmission (eg, myasthenia gravis [MG], Lambert-Eaton myasthenic syndrome [LEMS])

 

Distinguishing LEMS from autoimmune forms of MG

 

Providing a quantitative autoantibody baseline for future comparisons in monitoring a patient's clinical course and response to immunomodulatory treatment

Profile Information
A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test Id Reporting Name Available Separately Always Performed
MGLEI MG Lambert-Eaton Interpretation, S No Yes
ARBI ACh Receptor (Muscle) Binding Ab Yes Yes
CCPQ P/Q-Type Calcium Channel Ab No Yes

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
ACMFS AChR Modulating Flow Cytometry, S No No
MUSK MuSK Autoantibody, S Yes No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If acetylcholine receptor (AChR)-binding antibodies are greater than 0.02 nmol/L, then AChR muscle modulating antibody will be performed at an additional charge.

 

If AChR-binding antibodies are 0.02 nmol/L or less, then muscle-specific kinase (MuSK) autoantibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances, then AChR muscle modulating antibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances and AChR muscle modulating antibody is negative, MuSK autoantibody will be performed at an additional charge.

 

For more information see Myasthenia Gravis/Lambert Eaton Syndrome Testing Algorithm

Method Name
A short description of the method used to perform the test

ARBI, CCPQ, MUSK: Radioimmunoassay (RIA)

ACMFS: Flow Cytometry

MGLEI: Medical Interpretation

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

MG/LEMS Evaluation, S

Aliases
Lists additional common names for a test, as an aid in searching

Acetylcholine Receptor (Muscle AChR) Antibodies

Ach Receptor Ab

AChR (Acetylcholine Receptor)

AChR Receptor Blocking Ab

Anti-Skeletal Muscle Antibodies

Binding, Blocking, and Modulating Abs

Blocking Ab

Muscle End-Plate Antibodies

MUSK

MuSK myasthenia

Myasthenia Gravis Antibodies

Myasthenia Gravis

Myoid Antibody

Thymoma

LEMS

LES

Lambert-Eaton Myasthenic syndrome

Lambert Eaton

Lambert-Eaton syndrome

P/Q

Calcium channel antibody

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If acetylcholine receptor (AChR)-binding antibodies are greater than 0.02 nmol/L, then AChR muscle modulating antibody will be performed at an additional charge.

 

If AChR-binding antibodies are 0.02 nmol/L or less, then muscle-specific kinase (MuSK) autoantibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances, then AChR muscle modulating antibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances and AChR muscle modulating antibody is negative, MuSK autoantibody will be performed at an additional charge.

 

For more information see Myasthenia Gravis/Lambert Eaton Syndrome Testing Algorithm

Specimen Type
Describes the specimen type validated for testing

Serum

Ordering Guidance

This test should not be requested in patients who have recently received radioisotopes, therapeutically or diagnostically, because of potential assay interference. The specific waiting period before specimen collection will depend on the isotope administered, the dose given, and the clearance rate in the individual patient. Specimens will be screened for radioactivity prior to analysis. Radioactive specimens received in the laboratory will be held for 1 week and assayed if sufficiently decayed or canceled if radioactivity remains.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Patient Preparation: For optimal antibody detection, specimen collection is recommended prior to initiation of immunosuppressant medication.

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 3 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Forms

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

2 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross Hemolysis Reject
Gross lipemia Reject
Gross Icterus Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
Frozen 28 days
Ambient 72 hours

Useful For
Suggests clinical disorders or settings where the test may be helpful

Confirming the autoimmune basis of a defect in neuromuscular transmission (eg, myasthenia gravis [MG], Lambert-Eaton myasthenic syndrome [LEMS])

 

Distinguishing LEMS from autoimmune forms of MG

 

Providing a quantitative autoantibody baseline for future comparisons in monitoring a patient's clinical course and response to immunomodulatory treatment

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If acetylcholine receptor (AChR)-binding antibodies are greater than 0.02 nmol/L, then AChR muscle modulating antibody will be performed at an additional charge.

 

If AChR-binding antibodies are 0.02 nmol/L or less, then muscle-specific kinase (MuSK) autoantibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances, then AChR muscle modulating antibody will be performed at an additional charge.

 

If unable to report AChR binding antibody due to interfering substances and AChR muscle modulating antibody is negative, MuSK autoantibody will be performed at an additional charge.

 

For more information see Myasthenia Gravis/Lambert Eaton Syndrome Testing Algorithm

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Myasthenia gravis (MG) and Lambert-Eaton myasthenic syndrome (LEMS) are acquired autoimmune disorders of neuromuscular transmission. MG is caused by pathogenic autoantibodies binding and potentially removing (modulation) the muscle's nicotinic acetylcholine receptor (AChR) from the surface of the neuromuscular junction. Serologically, the detection of AChR binding antibody provides the best diagnostic sensitivity. However, the presence of both AChR binding and modulating activity improves diagnostic accuracy. A subset of patients who are AChR seronegative will have muscle-specific kinase (MuSK) antibodies.

 

LEMS is caused by autoantibodies binding to motor nerve terminal's voltage-gated P/Q-type calcium channel. Synaptic transmission fails when autoantibodies cause a critical loss of junctional cation channel proteins that activate the muscle action potential.

 

Both MG and LEMS can affect children as well as adults, although LEMS is very rare in children. In adults MG is 10 times more frequent than LEMS, but it is sometimes difficult to distinguish the two disorders clinically. Electrophysiological testing is extremely helpful in distinguishing these 2 disorders. MG patients have decrements of compound muscle action potential (CMAP) amplitudes on repetitive stimulation whereas LEMS has immediate and dramatic post exercise facilitation (elevation) of CMAP amplitudes. Neoplasms associated with LEMS or MG are an endogenous source of the antigens driving production of the autoantibodies that characterize each disorder. In adults with MG, there is at least a 20% occurrence of thymoma and, very rarely (<1%), extrathymic cancers. LEMS is frequently associated (80%) with small-cell lung carcinoma (SCLC). Thus far, MuSK antibody associated MG has not been associated with any neoplasm.

 

The diagnostic sensitivity of these tests depends on the disease severity and duration of symptoms. AChR binding antibodies may be undetectable for 6 to 12 months after MG symptom onset and similarly P/Q-type calcium channel antibody may be undetectable for 6 to 12 months after LEMS onset. Only about 5% of adult patients with generalized MG who are not immunosuppressed remain seronegative for muscle AChR beyond 12 months. Although immunotherapy is universally beneficial for MG, in LEMS resection of the identified SCLC and initiation of 3,4-diaminopyridine, which facilitates acetylcholine release by increasing presynaptic calcium concentration, is most beneficial.

 

Note: Single antibody tests may be requested in the follow-up of patients with positive results previously documented in this laboratory.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Test ID

Reporting name

Methodology

Reference value

MGLEI

MG Lambert-Eaton Interpretation, S

Interpretation

NA

ARBI

ACh Receptor (Muscle) Binding Ab

Radioimmunoassay (RIA)

< or =0.02 nmol/L

CCPQ

P/Q-Type Calcium Channel Ab

RIA

< or =0.02 nmol/L

Reflex Information:

Test ID

Reporting name

Methodology

Reference value

ACMFS

AChR Modulating Flow Cytometry, S

Flow cytometry

Negative

MUSK

MuSK Autoantibody, S

RIA

< or =0.02 nmol/L

Interpretation
Provides information to assist in interpretation of the test results

Positive results in this antibody evaluation are indicative of an autoimmune neuromuscular junction disorder. These results should be interpreted in the appropriate clinical and electrophysiological context.

 

In the presence of either acetylcholine receptor antibodies or P/Q antibodies, a paraneoplastic basis should be considered with thymoma being the most commonly associated tumor with myasthenia gravis and small cell lung cancer being the most commonly associated cancer with Lambert-Eaton myasthenic syndrome. Currently, muscle-specific kinase antibody positive myasthenia gravis is not associated with a paraneoplastic etiology.

 

Negative results do not exclude the diagnosis of an autoimmune neuromuscular junction disorder. If clinical suspicion remains and symptoms persistent or worsen consider retesting.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Specimens should be collected prior to administration of immunosuppressant therapy as this may reduce the diagnostic sensitivity of the assay; the neurological diagnosis is further confounded if steroid myopathy develops.

 

These results should only be interpreted in the appropriate clinical and electrophysiological context and are not diagnostic in isolation.

 

Positive muscle acetylcholine receptor (AChR) may occur in autoimmune liver disorders and in patients with graft-versus-host disease and recipients of D-penicillamine.

 

Weakly positive results may occur with hypergammaglobulinemia and should be interpreted with caution in the appropriate clinical context.

 

AChR modulating antibodies will only be performed if AChR binding antibodies are present or if there is an interfering substance present that precludes testing for AChR binding antibodies.

 

Seropositive rates and quantitative results differ across laboratories and patient results tested at different laboratories should not be treated equivalently.

 

The presence of alpha-bungarotoxin antibodies may interfere with the AChR muscle binding antibody assay and therefore if detected, AChR binding results will not be reported.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Lennon VA. Serological profile of myasthenia gravis and distinction from the Lambert-Eaton myasthenic syndrome. Neurology. 1997;48(Suppl 5):S23-S27. doi:10.1212/WNL.48.Suppl_5.23S

2. Harper CM, Lennon VA: Lambert-Eaton syndrome. In: Kaminski HJ, ed. Current Clinical Neurology: Myasthenia Gravis and Related Disorders. 2nd ed. Humana Press; 2008;209-226

3. Hoch W, McConville J, Helms S, Newsom-Davis J, Melms A, Vincent A. Auto-antibodies to the receptor tyrosine kinase MuSK in patients with myasthenia gravis without acetylcholine receptor antibodies. Nat Med. 2001;7(3):365-368. doi:10.1038/85520

4. Shelly S, Paul P, Bi H, et al. Improving accuracy of myasthenia gravis autoantibody testing by reflex algorithm. Neurology. 2020;95(22):e3002-e3011. doi:10.1212/WNL.0000000000010910

Method Description
Describes how the test is performed and provides a method-specific reference

Radioimmunoassay:

(125)I-labeled recombinant human antigens or labeled receptors are incubated with patient sample. After incubation, anti-human IgG is added to form an immunoprecipitate. The amount of (125)I-labeled antigen in the immunoprecipitate is measured using a gamma-counter. The amount of gamma emission in the precipitate is proportional to the amount of antigen-specific IgG in the sample. Results are reported as units of precipitated antigen (nMol) per L of patient sample.(Griesmann GE, Kryzer TJ, Lennon VA: Autoantibody profiles of myasthenia gravis and Lambert-Eaton myasthenic syndrome. In: Rose NR, Hamilton RG, et al. eds. Manual of Clinical and Laboratory Immunology. 6th ed. ASM Press; 2002:1005-1012; Jones AL, Flanagan EP, Pittock SJ, et al: Responses to and outcomes of treatment of autoimmune cerebellar ataxia in adults. JAMA Neurol. 2015;72[11]:1304-1312. doi:10.1001/jamaneurol.2015.2378)

 

Flow Cytometry:

This method uses flow cytometry to measure the loss of acetylcholine receptor (AChR) molecules expressed on the surface of live cells expressing AChR on the cell surface. The cell line used is an immortalized human rhabdomyosarcoma cell line that expresses endogenous muscle-type nicotinic AChR on its surface. Cells are plated in a 96-well plate and cultured 72 hours prior to the addition of patient sample for an additional 18 to 22 hours to enable internalization of AChR receptors (modulation). Modulation is then stopped by placing cells on ice. The amount of remaining AChRs on the cell surface is measured by flow cytometry. On ice, cells are incubated with a recombinant rat monoclonal antibody against alpha-subunit of the AChR followed by a secondary goat anti-rat IgG antibody conjugated with APC. The amount of AChR on the cell surface is proportional to the median fluorescence intensity (MFI) of allophycocyanin (APC). To calculate the amount of modulation (ie, % loss of AChR) the APC MFI is compared between cells treated with patient sample and cells treated with serum lacking AChR modulating antibodies. Background signal is established in each experiment utilizing cells stained with secondary antibody alone (no patient sera). The percent loss of AChR is calculated as 1-[(Patient MFI-Background MFI)/(Negative calibrator MFI - Background MFI)]*100%.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Profile tests: Monday through Sunday; Reflex tests: Varies

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

3 to 10 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

28 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

86041

86596

86043 (if appropriate)

86366 (if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
MGLE MG/LEMS Evaluation, S 97566-4
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
8338 ACh Receptor (Muscle) Binding Ab 97558-1
81185 P/Q-Type Calcium Channel Ab 94349-8
34273 MG Lambert-Eaton Interpretation, S 69048-7

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports