Test Catalog

Test Id : MPLFM

MPL Exon 10 Mutation Detection, Bone Marrow

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnosis or differential diagnosis of myeloproliferative disorders by MPL gene analysis using bone marrow specimens

Method Name
A short description of the method used to perform the test

Sanger Sequencing

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

MPL Exon 10 Mutation, BM

Aliases
Lists additional common names for a test, as an aid in searching

MPL S505

MPL W515

Myeloproliferative leukemia virus oncogene

MPL

PMF

MPN

ET

Primary Myelofibrosis

Essential Thrombocythemia

Specimen Type
Describes the specimen type validated for testing

Bone Marrow

Shipping Instructions

Specimen must arrive within 7 days of collection.

Necessary Information

The following information is required:

1. Pertinent clinical history

2. Clinical or morphologic suspicion

3. Date of collection

4. Specimen source

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Container/Tube:

Preferred: Lavender top (EDTA)

Acceptable: Yellow top (ACD solution B)

Specimen Volume: 2 mL

Collection Instructions:

1. Invert several times to mix bone marrow.

2. Send specimen in original tube. Do not aliquot.

3. Label specimen as bone marrow.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

1 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Moderately to severely clotted Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Bone Marrow Ambient (preferred) 7 days
Refrigerated 7 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

Diagnosis or differential diagnosis of myeloproliferative disorders by MPL gene analysis using bone marrow specimens

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Mutations in the JAK2, CALR and MPL genes are considered driver events in the BCR-ABL1 negative myeloproliferative neoplasms (MPN) including polycythemia vera (PV), primary myelofibrosis (PMF) and essential thrombocythemia (ET). The JAK2 V617F mutation occurs in 95% to 98% of patients with PV, 50% to 60% of patients with PMF and 50% to 60% of patients with ET respectively at diagnosis. Other JAK2 mutations in exon 12-15 occur in the remaining patients with PV. Mutations in the CALR gene occur in 20% to 30% of patients with PMF and 20% to 30% of patients with ET at diagnosis. A 52 base pairs deletion (53%) and a 5 bp deletion (32%) are the most common mutations in the CALR gene while other types of mutations may occur in the remaining cases. MPL exon 10 mutations occur in 5% to 10% of patients with PMF and 5% to 10% of patients with ET. Mutations in JAK2, CALR and MPL are mutually exclusive. The JAK2 V617F mutation is detected by quantitative polymerase chain reaction (PCR). The CALR mutations are detected by PCR targeting exon 9. The MPL mutations in exon 10 are detected by Sanger sequencing. All mutations in JAK2, CALR and MPL can also be detected by next generation of sequencing (NGS). In addition to the mutations in JAK2, CALR and MPL, mutations in many other genes including ASXL1, TET2, DNMT3A, SRSF2, SF3B1, U2AF1, ZRSR2, EZH2, IDH1, IDH2, CBL, KRAS, NRAS, STAG2, and TP53 can occur in MPN. These additional mutations are more frequent in PMF and advanced disease, as compared to PV and ET. It is known that mutations in the ASXL1, SRSF2, U2AF1, EZH2, IDH1 and IDH2 are correlated with a poor prognostic risk. While a single gene test on JAK2, CALR and MPL can be clinically useful, all above mentioned gene mutations can be detected by NGS.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

An interpretive report will be provided.

Interpretation
Provides information to assist in interpretation of the test results

The results will be reported as 1 of 2 states:

-Negative for myeloproliferative leukemia virus oncogene (MPL) exon 10 mutation

-Positive for MPL exon 10 mutation

 

If the result is positive, a description of the mutation at the nucleotide level and the altered protein sequence is reported.

 

Positive mutation status is highly suggestive of a myeloproliferative neoplasm but must be correlated with clinical and other laboratory features for a definitive diagnosis. Negative mutation status does not exclude the presence of a myeloproliferative or other neoplasm.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

A positive result is not specific for a particular diagnosis, and clinicopathologic correlation is necessary in all cases.

 

A negative result does not exclude the presence of a myeloproliferative or other neoplasm.

Supportive Data

Analytical sensitivity is approximately 20% meaning there must be about 20% of the altered DNA in the specimen for reliable detection.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Klampfl T, Gisslinger H, Harutyunyan AS, et al. Somatic mutation of calreticulin in myeloproliferative neoplasms. N Engl J Med. 2013;369(25):2379-2390

2. Rumi E, Pietra D, Ferretti V, et al. JAK2 or CALR mutation status defines subtypes of essential thrombocythemia with substantially different clinical course and outcomes. Blood. 2014;123(10):1544-1551

3. Greenfield G, McMullin MF, Mils K. Molecular pathogenesis of the myeloproliferative neoplasms. J Hematol Oncol. 2021;14(1):103

4. Khoury JD, Solary E, Abla O, et al. The 5th edition of the World Health Organization classification of haematolymphoid tumors: myeloid and histiocytic/dendritic neoplasms. Leukemia 2022; 36:1703-1719.

Method Description
Describes how the test is performed and provides a method-specific reference

Genomic DNA is extracted from bone marrow, and the MPL exon 10 amplified using standard polymerase chain reaction. The entire exon 10 sequence is obtained using Sanger sequencing (BigDye terminator V3.1 cycle sequencing kid from Applied Bioscience) with analysis on an automated genetic analyzer.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 8 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

Bone marrow: 2 weeks; DNA: 1 year

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Jacksonville

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

81339

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
MPLFM MPL Exon 10 Mutation, BM 75033-1
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
618662 Final Diagnosis 69047-9
618663 Method 85069-3
618664 Signing Pathologist 18771-6
618666 Additional Information 48767-8
618667 Disclaimer 62364-5

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.