Test Catalog

Test Id : MPNML

MPL Exon 10 Sequencing, Reflex, Varies

Useful For
Suggests clinical disorders or settings where the test may be helpful

Aiding in the distinction between a reactive cytosis and a myeloproliferative neoplasm when JAK2 V617F testing result is negative

 

Evaluates for variants in MPL in an algorithmic process for MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies

Method Name
A short description of the method used to perform the test

Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.

 

Sanger Sequencing

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

MPL Exon 10 Sequencing, Reflex

Specimen Type
Describes the specimen type validated for testing

Varies

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Paraffin-embedded bone marrow aspirate clot or biopsy blocks
Slides
Paraffin shavings
Moderately to severely clotted
Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Varies Varies

Useful For
Suggests clinical disorders or settings where the test may be helpful

Aiding in the distinction between a reactive cytosis and a myeloproliferative neoplasm when JAK2 V617F testing result is negative

 

Evaluates for variants in MPL in an algorithmic process for MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

The JAK2 V617F variant is present in 95% to 98% of patients with polycythemia vera, 50% to 60% of patients with primary myelofibrosis (PMF), and 50% to 60% of patients with essential thrombocythemia (ET). Detection of the JAK2 V617F is helps establish the diagnosis of a myeloproliferative neoplasm (MPN). However, a negative JAK2 V617F result does not indicate the absence of MPN. Other important molecular markers in BCR::ABL1-negative MPN include CALR exon 9 alterations (20%-30% of PMF and ET) and MPL exon 10 alterations (5%-10% of PMF and 3%-5% of ET). Variants in JAK2, CALR, and MPL are essentially mutually exclusive. A CALR variant is associated with decreased risk of thrombosis in both ET and PMF and confers a favorable clinical outcome in patients with PMF. A triple negative (JAK2 V617F, CALR, and MPL-negative) genotype is considered a high-risk molecular signature in PMF.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Only orderable as a reflex. For more information see MPNCM / Myeloproliferative Neoplasm, CALR with Reflex to MPL, Varies.

 

An interpretive report will be provided.

Interpretation
Provides information to assist in interpretation of the test results

The results will be reported as 1 of the 3 following states:

-Positive for CALR variant

-Positive for MPL variant

-Negative for CALR and MPL variants

 

Positive variant status is highly suggestive of a myeloid neoplasm and clinicopathologic correlation is necessary in all cases.

 

Negative variant status does not exclude the presence of a myeloproliferative neoplasm or other neoplasms.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

A positive result is not specific for a particular subtype of myeloproliferative neoplasm and clinicopathologic correlation is necessary in all cases.

 

A negative result does not exclude the presence of a myeloproliferative neoplasm or other neoplastic process.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Klampfl T, Gisslinger H, Harutyunyan AS, et al. Somatic mutation of calreticulin in myeloproliferative neoplasms. N Engl J Med. 2013;369(25):2379-2390

2. Nangalia J, Massie CE, Baxter EJ, et al. Somatic CALR mutation in myeloproliferative neoplasms with nonmutated JAK2. N Engl J Med. 2013;369(25):2391-2405

3. Rotunno G, Mannarelli C, Guglielmelli P, et al. Impact of calreticulin mutations on clinical and hematological phenotype and outcome in essential thrombocythemia. Blood. 2014;123(10):1552-1555

4. Tefferi A, Lasho TL, Finke CM, et al. CALR vs JAK2 vs MPL-mutated or triple-negative myelofibrosis: clinical, cytogenetic and molecular comparisons. Leukemia. 2014;28(7):1472-1477

5. Pikman Y, Lee BH, Mercher T, et al. MPLW515L is a novel somatic activating mutation in myelofibrosis with myeloid metaplasia. PLoS Med. 2006;3(7):e270

6. Pardanani AD, Levine RL, Lasho T, et al. MPL515 mutations in myeloproliferative and other myeloid disorders: a study of 1182 patients. Blood. 2006;108(10):3472-3476

Method Description
Describes how the test is performed and provides a method-specific reference

Genomic DNA is extracted, and Sanger sequencing is used to evaluate for alterations in MPL, exon 10. The sensitivity of this assay is approximately 20%, such that samples containing lower percentages of altered DNA will appear negative.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

7 to 10 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

Extracted DNA: 3 months

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

81339-MPL (myeloproliferative leukemia virus oncogene, thrombopoietin receptor, TPOR) (eg, myeloproliferative disorder), exon 10 sequence

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports