Test Catalog

Test Id : PHEPU

Previous Viral Hepatitis (Unknown Type), Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Determining if an individual has been infected following exposure to an unknown type of viral hepatitis virus

 

Obtaining baseline serologic markers of an individual exposed to a source with an unknown type of hepatitis

 

Determining immunity to hepatitis A and B viral infections

Profile Information
A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test Id Reporting Name Available Separately Always Performed
HAVTA Hepatitis A Virus Total Ab, S Yes Yes
HBAG HBs Antigen, S Yes Yes
HBAB HBs Antibody, S Yes Yes
HBC HBc Total Ab, S Yes Yes
HCVDX HCV Ab w/Reflex to HCV PCR, S Yes Yes

Reflex Tests
Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.

Test Id Reporting Name Available Separately Always Performed
HBGNT HBs Antigen Confirmation, S No No
HCVQN HCV RNA Detect/Quant, S Yes No

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If hepatitis C virus (HCV) antibody is reactive, then HCV RNA detection and quantification by real-time reverse transcription polymerase chain reaction will be performed at an additional charge.

 

If hepatitis B virus surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.

 

For more information see:

-Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management.

-Hepatitis C: Testing Algorithm for Screening and Diagnosis

Method Name
A short description of the method used to perform the test

HAVTA, HBAG, HBAB, HBC, HCVDX, HBGNT: Electrochemiluminescence Immunoassay (ECLIA)

HCVQN: Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Previous Hepatitis Profile

Aliases
Lists additional common names for a test, as an aid in searching

PHEPU

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If hepatitis C virus (HCV) antibody is reactive, then HCV RNA detection and quantification by real-time reverse transcription polymerase chain reaction will be performed at an additional charge.

 

If hepatitis B virus surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.

 

For more information see:

-Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management.

-Hepatitis C: Testing Algorithm for Screening and Diagnosis

Specimen Type
Describes the specimen type validated for testing

Serum SST

Necessary Information

Date of collection is required.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).

Supplies: Sarstedt 5 mL Aliquot Tube (T914)

Collection Container/Tube: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 2.6 mL

Collection Instructions:

1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot 1.8 mL serum into a plastic vial and ship frozen (preferred).

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Forms

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

1.8 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-inactivated specimen Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum SST Frozen (preferred) 84 days
Refrigerated 6 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

Determining if an individual has been infected following exposure to an unknown type of viral hepatitis virus

 

Obtaining baseline serologic markers of an individual exposed to a source with an unknown type of hepatitis

 

Determining immunity to hepatitis A and B viral infections

Testing Algorithm
Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

If hepatitis C virus (HCV) antibody is reactive, then HCV RNA detection and quantification by real-time reverse transcription polymerase chain reaction will be performed at an additional charge.

 

If hepatitis B virus surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.

 

For more information see:

-Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management.

-Hepatitis C: Testing Algorithm for Screening and Diagnosis

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Hepatitis A:

Hepatitis A virus (HAV) is an RNA virus that accounts for 20% to 25% of viral hepatitis in adults in the United States. HAV infection is spread by the oral/fecal route and produces acute hepatitis that follows a benign, self-limited course. Spread of the disease is usually associated with contaminated food or water caused by poor sanitary conditions. Outbreaks frequently occur in overcrowded situations and institutions or high-density centers such as prisons and healthcare centers. Epidemics may occur following floods or other disaster situations. Chronic carriers of HAV have never been observed.

 

Hepatitis B:

Hepatitis B virus (HBV) is a DNA virus that is endemic throughout the world. The infection is spread primarily through percutaneous contact with infected blood products (eg, blood transfusion, sharing of needles among injection drug users). The virus is found in various human body fluids and is known to be spread through oral and genital contact. HBV can be transmitted from mother to child during delivery through contact with blood and vaginal secretions; it is not commonly transmitted transplacentally.

 

After a course of acute illness, HBV persists in approximately 10% of patients. Some chronic carriers are asymptomatic, while others develop chronic liver disease, including cirrhosis and hepatocellular carcinoma.

 

Hepatitis C:

Hepatitis C virus (HCV) is an RNA virus recognized as the cause of most cases of posttransfusion hepatitis that is a significant cause of morbidity and mortality worldwide. HCV is transmitted through contaminated blood or blood products or close, personal contact. HCV shows a high rate of progression (~75%) to chronic disease. In the United States, HCV infection is quite common, with an estimated 3.5 to 4 million chronic HCV carriers. Cirrhosis and hepatocellular carcinoma are sequelae of chronic HCV.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

HEPATITIS B VIRUS SURFACE ANTIGEN

Negative

 

HEPATITIS B VIRUS SURFACE ANTIGEN CONFIRMATION

Negative

 

HEPATITIS B VIRUS SURFACE ANTIBODY, QUALITATIVE/QUANTITATIVE

Hepatitis B Surface Antibody

Unvaccinated: Negative

Vaccinated: Positive

 

HEPATITIS B VIRUS SURFACE ANTIBODY, QUANTITATIVE

Unvaccinated: <8.5 mIU/mL

Vaccinated: > or =11.5 mIU/mL

 

HEPATITIS B VIRUS CORE TOTAL ANTIBODIES

Negative

 

HEPATITIS A VIRUS TOTAL ANTIBODY

Unvaccinated: Negative

Vaccinated: Positive

 

HEPATITIS C VIRUS ANTIBODY

Negative

 

HEPATITIS C VIRUS RNA DETECTION and QUANTIFICATION by REAL-TIME RT-PCR

Undetected

 

Interpretation depends on clinical setting. For more information see Viral Hepatitis Serologic Profiles.

Interpretation
Provides information to assist in interpretation of the test results

Interpretation depends on clinical setting. For more information see Viral Hepatitis Serologic Profiles.

 

Hepatitis A:

Hepatitis A virus (HAV)-specific total antibodies are almost always detectable by the onset of symptoms of acute hepatitis A (usually 15 to 45 days after exposure). The initial antibody consists almost entirely of the IgM subclass of antibody. Anti-HAV IgM usually falls to undetectable levels 3 to 6 months after infection. Anti-HAV IgG levels rise quickly once the virus is cleared and persist for many years.

 

Hepatitis B:

Hepatitis B virus surface antigen (HBsAg) is the first serologic marker appearing in the serum 6 to 8 weeks following hepatitis B virus (HBV) infection. A confirmed positive result for HBsAg is indicative of acute or chronic hepatitis B. In acute cases, HBsAg usually disappears 1 to 2 months after the onset of symptoms. Anti-HBs appears with the resolution of HBV infection after the disappearance of HBsAg. Anti-HBs also appears as the immune response following a course of inoculation with the hepatitis B vaccine.

 

Hepatitis B virus core antibody (anti-HBc) appears shortly after the onset of symptoms of HBV infection and may be the only serologic marker remaining years after exposure to hepatitis B.

 

Hepatitis C:

Hepatitis C virus-specific antibodies are usually not detectable during the first 2 months after exposure, but they are almost always detectable by the late convalescent stage of infection. HCV antibodies are not neutralizing and do not provide immunity.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Positive hepatitis B surface antigen (HBsAg) results may need to be reported by the healthcare providers to their communicable disease surveillance units of state departments of health, as required by law in various states.

 

Type-specific tests should be used to evaluate individuals who have been exposed to a source with a known type of hepatitis (eg, hepatitis A, hepatitis B, hepatitis C).

 

Serum specimens from individuals taking biotin supplements at 20 mg or more per day may have false-positive results for HAV total antibody and HBc total antibody, as well as false-negative results for HBsAg and HCV total antibody, due to interference of biotin with the assay. Such individuals should stop taking these biotin-containing dietary supplements for minimum 12 hours before blood collection for this test.

 

Performance characteristics have not been established for the following specimen characteristics:

-Grossly icteric (total bilirubin level of >25 mg/dL)

-Grossly lipemic (intralipid level of >1000 mg/dL)

-Grossly hemolyzed (hemoglobin level of >500 mg/dL)

-Containing particulate matter

-Cadaveric specimens

-Immunocompromised or immunosuppressed specimens

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. De Paula VS. Laboratory diagnosis of hepatitis A. Future Virology. 2012;7(5):461-472

2. American Association for the Study of Liver Diseases and Infectious Diseases Society of America: HCV guidance: Recommendations for testing, managing, and treating hepatitis C. Accessed December 20, 2023. Available at www.hcvguidelines.org/contents

3. WHO guidelines on hepatitis B and C testing. World Health Organization, 2017. Accessed December 20, 2023. Available at www.who.int/publications/i/item/9789241549981

4. Conners EE, Panagiotakopoulos L, Hofmeister MG, et al. Screening and testing for hepatitis B virus infection: CDC Recommendations – United States, 2023. MMWR Recomm Rep. 2023;72(1):1-25

Method Description
Describes how the test is performed and provides a method-specific reference

Hepatitis A Virus Total Antibody:

The Elecsys Anti-HAV (hepatitis A virus) II assay is based on the competitive immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HAV-specific antibodies in the patient’s serum binds with added HAV antigen in the reaction. After addition of biotinylated monoclonal anti-HAV and streptavidin-coated microparticles, patient’s anti-HAV form a sandwich complex with the HAV antigen and the ruthenium-labeled anti-HAV antibody which becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test result is determined automatically with the assay-specific software in comparing the electrochemiluminescence signal generated in the patient’s sample to the signal cutoff index (COI) value set from reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HAV II. Roche Diagnostics; v3.0, 11/2022) 

 

Hepatitis B Virus Surface Antigen:

The Elecsys HBsAg (hepatitis B surface antigen) II assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analzyer. HBsAg present in the patient’s sample reacts with two biotinylated monoclonal anti-HBs, and a mixture of monoclonal anti-HBs and polyclonal anti-HBsAg antibodies labeled with a ruthenium complex react to form a sandwich complex. After addition of streptavidin-coated microparticles, the complexes become bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test results for each patient’s sample is determined by comparing the electrochemiluminescence signal generated from the reaction product to the COI value set from reagent lot-specific assay calibration.(Package insert: Elecsys HBsAG II. Roche Diagnostics; v3.0, 02/2022)

 

Hepatitis B Surface Antigen Confirmation:

The Elecsys HBsAg II Auto Confirm assay is performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. This test is based on 2 parallel measurements. For the first measurement, the sample is treated with the control pretreatment reagent (PT2) prior to immunoreaction. This measurement serves as a reference. For the second measurement the sample is treated with the confirmatory pretreatment reagent (PT1) prior to immunoreaction. During incubation with confirmatory pretreatment, unlabeled polyclonal anti-HBsAg antibodies are bound to the sample HBsAg and thereby block the binding sites for the labeled antibodies used in the following immunoreaction. The confirmation result (%) is automatically assessed by determining the ratio of both measurements.

 

During testing, the auto-diluted sample is incubated with control pretreatment and confirmatory pretreatment, followed by formation of sandwich complexes of biotinylated monoclonal anti-HBsAg antibodies and a mixture of monoclonal anti-HBsAg antibody and polyclonal anti-HBsAg antibodies labeled with a ruthenium complex. After addition of streptavidin-coated microparticles, the complexes become bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are then washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Results are determined by comparing the electrochemiluminescence signal generated from the reaction product to the COI value set from reagent lot-specific assay calibration. The confirmation result (%) is calculated from the ratio of the COI obtained for the measurement with confirmatory pretreatment to the COI obtained for the measurement with control pretreatment.(Package Insert: Elecsys HBsAg II Auto Confirm, Roche Diagnostics; v1.0, 12/2020)

 

Hepatitis B Virus Surface Antibody:

The Elecsys Anti-HBs (hepatitis B virus surface) assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescent immunoassay on the automated cobas e 801 immunochemistry analyzer. Anti-HBs present in patient’s serum sample reacts with the biotinylated HBsAg (ad and ay subtypes) and HBsAg (ad/ay) labeled with a ruthenium complex to form a sandwich complex. After the addition of streptavidin-coated microparticles, the complexes bind to a solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. The emission signal generated is directly proportional to the concentration of anti-HBs present in the patient’s serum sample.(Package insert: Elecsys Anti-HBs. Roche Diagnostic; v1.0, 2019)

 

Hepatitis B Virus Core Total Antibody:

The Elecsys Anti-HBc (hepatitis B viral core) II assay is based on the competitive immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 analyzer. Anti-HBc present in the patient’s sample are pretreated first with a reducing reagent, and after the addition of hepatitis B virus core antigen (HBcAg), complexes are formed with anti-HBc in the sample. The remaining unbound sites on the HBcAg become occupied after addition of biotinylated antibodies and ruthenium complex-labeled antibodies specific for HBcAg, together with streptavidin-coated microparticles. The entire complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. After unbound substances are washed away, voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Results are determined by comparing the electrochemiluminescence signal generated from the reaction product of the sample to the COI value set from assay reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HBc II. Roche Diagnostics; v1.0, 04/2022)

 

Hepatitis C Virus Antibody:

The Elecsys Anti-HCV (hepatitis C virus) II assay is based on sandwich immunoassay principle and performed on the fully automated cobas e 801 electrochemiluminescence immunoassay analyzer. During the first incubation, antibodies to HCV in the patient’s sample, biotinylated HCV-specific antigens and a reagent containing HCV-specific antigens labeled with a ruthenium complex to form a sandwich complex. In the second incubation, after addition of streptavidin-coated microparticles, the complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then washed away, and application of a voltage to the electrode induces chemiluminescent emissions, which are measured by a photomultiplier. Test result for each patient’s sample is determined automatically by the assay-specific software program by comparing the electrochemiluminescence signal obtained from the sample with the COI value set from reagent lot-specific assay calibrations.(Package insert: Elecsys Anti-HCV II. Roche Diagnostics; v1.0, 03/2023)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Profile tests: Monday through Friday; Reflex tests: Varies

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

Same day/1 to 2 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

86704

86706

86708

86803

87340

87341 (if appropriate)

87522 (if appropriate)

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
PHEPU Previous Hepatitis Profile 92890-3
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
HBC HBc Total Ab, S 13952-7
HB_AB HBs Antibody, S 10900-9
HBSQN HBs Antibody, Quantitative, S 5193-8
H_BAG HBs Antigen, S 5196-1
HCVA4 HCV Ab, S 40726-2
HAVT Hepatitis A Virus Total Ab, S 13951-9

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports