Test Catalog

Test Id : RFPN

Rheumatoid Factor Panel, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

Evaluating patients at-risk of rheumatoid arthritis (RA) or features of inflammatory arthritis

 

Differentiating the antibody isotype profile in patients positive for rheumatoid factor (RF)

 

Aid in the risk stratification of RF-seropositive patients with RA

Highlights

This test is useful for the differentiation of rheumatoid factor (RF) antibodies based on the presence of IgM or IgA antibody isotypes in patients with or at-risk for rheumatoid arthritis (RA).

 

The combination of RF IgM and RF IgA results provides the highest sensitivity for RA while IgA isotype results provide the highest specificity and positive likelihood ratio for RA diagnosis. The presence of RF IgA isotype may also be relevant in the risk stratification of RA for erosive joint disease.

 

Together with anti-citrullinated peptide/protein IgG antibody testing, isotype analysis may be an alternative to RF testing.

Profile Information
A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test Id Reporting Name Available Separately Always Performed
RFA Rheumatoid Factor IgA, S No Yes
RFM Rheumatoid Factor IgM, S No Yes

Method Name
A short description of the method used to perform the test

Chemiluminescent Immunoassay

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Rheumatoid Factor Panel, S

Aliases
Lists additional common names for a test, as an aid in searching

FRGAM

FRFIG

Autoimmune Hearing Loss (SNHL)

RF

Rheumatoid Factor

Rheumatoid Arthritis

Sjogren's Syndrome

Systemic Lupus Erythematosus (SLE)

Specimen Type
Describes the specimen type validated for testing

Serum

Additional Testing Requirements

Rheumatoid factor (RF) IgA and RF IgM should be tested in combination with CCP / Cyclic Citrullinated Peptide Antibodies, IgG, Serum; or following positive or equivocal results for either RHUT / Rheumatoid Factor, Serum; or RAPAN / Rheumatoid Arthritis Panel, Serum.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

0.3 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-treated specimens Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
Frozen 28 days
Ambient 48 hours

Useful For
Suggests clinical disorders or settings where the test may be helpful

Evaluating patients at-risk of rheumatoid arthritis (RA) or features of inflammatory arthritis

 

Differentiating the antibody isotype profile in patients positive for rheumatoid factor (RF)

 

Aid in the risk stratification of RF-seropositive patients with RA

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Rheumatoid arthritis (RA) is a chronic systemic autoimmune disease characterized by interactions between the environment, specific genetic risk factors, and the human immune system. It affects about 0.6% of the United States population with a global prevalence of 0.24%.(1) Clinically, RA is typified by progressive damage of synovial joints, inflammation, production of diverse autoantibodies, and variable extra-articular manifestations.(1,2) To facilitate early diagnosis, the American College of Rheumatology/European League Against Rheumatism 2010 RA classification criteria recommend testing for rheumatoid factors (RF) and anti-citrullinated protein antibodies (ACPA).(2) RF are autoantibodies directed against the Fc portion of immunoglobulin, while ACPA are directed against peptides and proteins containing citrulline, a modified form of the amino acid arginine.(3,4) In addition to the defined interpretations for anti-cyclic citrullinate peptide (CCP) and RF antibodies, the classification criteria also endorse the combination of specific clinical features and inflammatory markers for RA diagnosis.

 

The clinical symptoms in the early phase of RA may be nonspecific with some patients demonstrating relatively low levels of antibodies to RF or anti-CCP antibodies, which may not fulfill the diagnostic criteria for disease. In addition, some patients with clinical features of RA may test negative for criteria antibodies, a phenomenon referred to as seronegative or ACPA-negative. While alternative diagnoses may be implicated in at-risk RA patients, determination of autoantibody isotypes for RF and other RA-associated autoantibodies have been reported to improve diagnostic accuracy and/or provide prognostic clues.(5-8) Thus, determination of multiple analytes of diverse antibody isotypes in patients seropositive for RA may be useful in risk stratification for joint erosive disease and other clinical manifestations such as cardiovascular or lung involvements.(5,7,8)

 

In routine clinical laboratory evaluation for RA, RF antibodies are generally detected and quantified using IgM RF or total (isotype-nonspecific) RF immunoassays and CCP IgG antibodies with a variety of solid-phase immunoassays, such the enzyme linked immunosorbent assay, chemiluminescence immunoassay (CIA), fluorescent enzyme immunoassay (FEIA), multiplexed immunoassay using manual or automated platforms.(5,6,9,10) With respect to RF antibody measurements, it has been established that separate determination of RF IgA and RF IgM antibodies is important in RA evaluation, as severe joint erosive disease is seen more in patients with significantly elevated IgA RF than in those who are IgA RF negative.(5,8,9) However, IgA RF is generally less sensitive than IgM RF for RA, and double positivity for IgM RF and IgA RF has a higher specificity for RA than either IgM RF or IgA RF.(9) Both tests should be offered in a panel, which is not intended to replace RF tests that detect IgA, IgG and IgM autoantibodies. The relevance of IgG RF in addition to IgA or IgM RF is of limited clinical value and not available for testing on the CIA or FEIA platforms due to this clinical limitation.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

RHEUMATOID FACTOR, IgA

Negative: <20 CU

Positive: > or =20 CU

Reference values apply to all ages.

 

RHEUMATOID FACTOR, IgM

Negative: <5.0 IU/mL

Positive: > or =5.0 IU/mL

Reference values apply to all ages.

Interpretation
Provides information to assist in interpretation of the test results

The presence of rheumatoid factor (RF) IgM or IgA at abnormal levels in association with anti-citrullinated peptide/protein antibodies has high specificity for a diagnosis of rheumatoid arthritis (RA). However, the presence of RF isotypes in any combination may be found in a variety of conditions, including Sjogren syndrome and hepatitis infections.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Some patients with rheumatoid arthritis (RA) may be negative for rheumatoid factor (RF) IgM or RF IgA but positive for RF antibody by nephelometry or anti-citrullinated peptide IgG antibodies. Negative results do not rule out a diagnosis of RA. All results must be interpreted in the appropriate clinical context and in association with other recommended laboratory tests disease evaluation. The performance characteristics of this assay have not been established for matrices other than serum.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Cross M, Smith E, Hoy D, et al. The global burden of rheumatoid arthritis: estimates from the global burden of disease 2010 study. Ann Rheum Dis. 2014;73:1316-1322

2. Aletaha D, Neogi T, Silman AJ, et al. 2010 Rheumatoid arthritis classification criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative. Arthritis Rheum. 2010;62:2569-2581

3. Schellekens GA, Visser H, de Jong BA, et al. The diagnostic properties of rheumatoid arthritis antibodies recognizing a cyclic citrullinated peptide. Arthritis Rheum. 2000;43:155-163

4. Derksen VFAM, Huizinga TWJ, van der Woude D. The role of autoantibodies in the pathophysiology of rheumatoid arthritis. Semin Immunopathol. 2017;39:437-446

5. Sieghart D, Platzer A, Studenic P, et al. Determination of autoantibody isotypes increases the sensitivity of serodiagnostics in rheumatoid arthritis. Front Immunol. 2018;9:876

6. Brink M, Hansson M, Mathsson-Alm L, et al. Rheumatoid factor isotypes in relation to antibodies against citrullinated peptides and carbamylated proteins before the onset of rheumatoid arthritis. Arthritis Res Ther. 2016;18:43

7. Kelmenson LB, Wagner BD, McNair BK, et al. Timing of Elevations of Autoantibody Isotypes Prior to Diagnosis of Rheumatoid Arthritis. Arthritis Rheumatol. 2020;72:251-261

8. Oka S, Higuchi T, Furukawa H, et al. Serum rheumatoid factor IgA, anti-citrullinated peptide antibodies with secretory components, and anti-carbamylated protein antibodies associate with interstitial lung disease in rheumatoid arthritis. BMC Musculoskelet Disord. 2022;23:46

9. Van Hoovels L, Vander Cruyssen B, Sieghart D, et al. IgA rheumatoid factor in rheumatoid arthritis. Clin Chem Lab Med. 2022;60:1617-1626

10. Van Hoovels L, Vander Cruyssen B, Sieghart D, et al. Multicentre study to improve clinical interpretation of rheumatoid factor and anti-citrullinated protein/peptide antibodies test results. RMD Open. 2022;8:e002099

Method Description
Describes how the test is performed and provides a method-specific reference

The Inova BIO-FLASH system uses paramagnetic beads as the solid surface upon which to bind the targeted antibody. The beads used in the rheumatoid factor (RF) IgA and IgM kits are coated with rabbit polyclonal antibodies as the capture antigen. The serum sample is diluted by the instrument and combined in a cuvette with the beads and assay buffer for 10 minutes at 37 degrees C. The beads are magnetized, and unbound materials are washed away. Detection antibody conjugated with isoluminol is added to the cuvette for another incubation at 37 degrees C. The RF IgA kits contain anti-human IgA conjugate, while the RF IgM kits contain anti human IgM conjugate. After an additional wash, trigger reagents are added to the cuvette to initiate a light reaction proportional to the amount of bound isoluminol conjugate. The light produced by the reaction is measured by a detector as relative light unit (RLU). The RLU is applied to the working curve on the instrument. The RF IgA is reported as chemiluminescent units (CU), while the RF IgM is reported in IU/mL traceable to WHO Reference Reagent W1066.(Package inserts: QUANTA Flash RF IgA. Inova Diagnostics, Inc; V 4, 07/2019; QUANTA Flash RF IgM. Inova Diagnostics, Inc; V 4, 07/2019)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Wednesday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

2 to 3 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

86431 x2

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
RFPN Rheumatoid Factor Panel, S In Process
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
RFM Rheumatoid Factor IgM, S 9338-5
RFA Rheumatoid Factor IgA, S 33313-8

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports