Test Catalog

Test Id : NSE

Neuron-Specific Enolase, Serum

Useful For
Suggests clinical disorders or settings where the test may be helpful

A follow-up marker in patients with neuron-specific enolase-secreting tumors of any type

 

An auxiliary test in the diagnosis of small cell lung carcinoma

 

An auxiliary test in the diagnosis of carcinoids, islet cell tumors, and neuroblastomas

 

An auxiliary tool in the assessment of comatose patients

Method Name
A short description of the method used to perform the test

Homogeneous Time-Resolved Fluorescence

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Neuron Specific Enolase, S

Aliases
Lists additional common names for a test, as an aid in searching

NSE Enolase

Specimen Type
Describes the specimen type validated for testing

Serum

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.

Forms

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

0.3 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia OK
Gross icterus Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 7 days
Ambient 5 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

A follow-up marker in patients with neuron-specific enolase-secreting tumors of any type

 

An auxiliary test in the diagnosis of small cell lung carcinoma

 

An auxiliary test in the diagnosis of carcinoids, islet cell tumors, and neuroblastomas

 

An auxiliary tool in the assessment of comatose patients

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Enolase is a glycolytic enzyme that catalyzes the conversion of 2-phosphoglycerate to phosphoenolpyruvate. Enolase exists in the form of several tissue-specific isoenzymes, consisting of homo or heterodimers of 3 different monomer-isoforms (alpha, beta, and gamma). Neuron-specific enolase (NSE) is a 78 kDa gamma-homodimer and represents the dominant enolase-isoenzyme found in neuronal and neuroendocrine tissues. Its levels in other tissues, except erythrocytes, are negligible. The biological half-life of NSE in body fluids is approximately 24 hours.

 

Due to this organ-specificity, concentrations of NSE in serum or, more commonly, cerebrospinal fluid (CSF) are often elevated in diseases that result in relative rapid (hours/days to weeks rather than months to years) neuronal destruction. Measurement of NSE in serum or CSF can therefore assist in the differential diagnosis of a variety of neuron-destructive and neurodegenerative disorders. The most common application is in the differential diagnosis of dementias, where elevated CSF concentrations support the diagnosis of rapidly progressive dementias, such as Creutzfeldt-Jacob Disease. NSE may also have utility as a prognostic marker in neuronal injury. For example, there is increasing evidence that elevated serum NSE levels correlate with a poor outcome in coma, particularly when caused by hypoxic insult.

 

NSE is frequently overexpressed by neural crest-derived tumors. Up to 70% of patients with small cell lung carcinoma (SCLC) have elevated serum NSE concentrations at diagnosis. Approximately 90% of patients with advanced SCLC will have serum levels above the healthy reference range. Other neuroendocrine tumors with frequent expression of NSE include carcinoids (up to 66% of cases), islet cell tumors (typically <40% of cases), and neuroblastoma (exact frequency of NSE expression unknown). NSE levels in NSE-secreting neoplasms correlate with tumor mass and tumor metabolic activity. High levels have, therefore, some negative prognostic value. Falling or rising levels are often correlated with tumor shrinkage or recurrence, respectively.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

< or =15 ng/mL

Serum markers are not specific for malignancy, and values may vary by method.

Interpretation
Provides information to assist in interpretation of the test results

Serum neuron-specific enolase (NSE) measurement has its greatest utility in the follow-up of patients with tumors of any type that have been shown to secrete NSE. With successful treatment, serum concentrations should fall with a half-life of approximately 24 hours. Persistent NSE elevations in the absence of other possible causes (see Cautions) suggest persistent tumor. Rising levels indicate tumor spread or recurrence in patients who had previously become NSE negative.

 

In the context of a patient with a lung mass, disseminated malignancy of unknown origin, or symptoms suggestive of paraneoplastic disease without identifiable tumor, elevated NSE levels suggest an underlying small cell lung carcinoma (SCLC).

 

In patients with suspected carcinoid, islet cell tumor, or neuroblastoma, who have no clear elevations in the primary tumor markers used to diagnose these conditions, an elevated serum NSE level supports the clinical suspicion.

-Carcinoid: chromogranin A, urinary 5-hydroxyindoleacetic acid, serum/blood 5-hydroxytryptamine (serotonin)

-Islet cell tumors: variety of peptide and amine-derived hormones, chromogranin A

-Neuroblastoma: vanillylmandelic acid and homovanillic acid

 

When considered alongside established outcome predictors of coma, such as Glasgow coma scale and other clinical predictors (papillary light responses, corneal reflexes, motor responses to pain, myoclonus, status epilepticus), electroencephalogram, sensory evoked potentials, measurement of serum NSE concentrations provides additional information. Elevated levels are indicative of a poor outcome. Currently, no established algorithms exist to combine serum NSE concentrations and the various other predictors into a composite score that gives clear predictive outcome information. The NSE measurement, therefore, needs to be considered in a qualitative or semi-quantitative fashion and carefully weighed against other predictors by a physician experienced in examining and managing coma patients.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

All neuron-specific enolase (NSE) test results must be considered in the clinical context, and interferences or artifactual elevations should be suspected if the clinical NSE test results are at odds with the clinical picture or other tests. The laboratory should be contacted for assistance in these situations.

 

Hemolysis can lead to significant artifactual NSE elevations since erythrocytes contain NSE.

 

Hemoglobin concentrations as low as 20 mg/dL were found to have an adverse effect on NSE testing.

 

Proton pump inhibitor treatment, hemolytic anemia, hepatic failure, and end-stage kidney failure can also result in artifactual NSE elevations.

 

Other false-positive results depend on the treating context. When performing NSE testing for tumor diagnosis or follow-up, epileptic seizure, brain injury, encephalitis, stroke, and rapidly progressive dementia might result in false-positive results. On the other hand, when NSE testing is performed to assist in neurological diagnosis, NSE-secreting tumors can represent a source of false-positive results.

 

NSE values can vary significantly between methods/assays. Serial follow-up should be performed with the same assay. If assays are changed, patients should have their baseline level reestablished. This assay is an immunometric assay and can, in rare situations, be affected by false-low results in the presence of extremely high NSE concentrations ("hooking") or autoantibodies to NSE.

 

In rare cases, some individuals can develop antibodies to mouse or other animal antibodies (often referred to as human anti-mouse antibodies [HAMA] or heterophile antibodies), which may cause interference in some immunoassays. Caution should be used in interpretation of results, and the laboratory should be alerted if the result does not correlate with the clinical presentation.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Burghuber OC, Worofka B, Schernthaner G, et al: Serum neuron-specific enolase is a useful tumor marker for small cell lung cancer. Cancer. 1990 Mar;65(6):1386-1390

2. Lamberts SW, Hofland LJ, Nobels FR: Neuroendocrine tumor markers. Front Neuroendocrinol. 2001 Oct;22(4):309-339

3. Aksamit AJ Jr, Preissner CM, Homburger HA: Quantitation of 14-3-3 and neuron-specific enolase proteins in CSF in Creutzfeldt-Jacob disease. Neurology. 2001 Aug;57(4):728-730

4. Riley RD, Heney D, Jones DR, et al: A systematic review of molecular and biological tumor markers in neuroblastoma. Clin Cancer Res. 2004 Jan;10(1 Pt 1);4-12

5. Portela-Gomes GM, Hacker GW, Weitgasser R: Neuroendocrine cell markers for pancreatic islets and tumors. Appl Immunohistochem Mol Morphol. 2004 Sep;12(3):183-192

6. Wijdicks EFM, Hijdra A, Young GB, Bassetti CL, Wiebe S, Quality Standards Subcommittee of the American Academy of Neurology: Practice parameter: prediction of outcome in comatose survivors after cardiopulmonary resuscitation (an evidence-based review). Neurology. 2006 Jul;67(2):203-210

7. Huang L, Zhou JG, Yao WX, et al: Systematic review and meta-analysis of the efficacy of serum neuron-specific enolase for early small cell lung cancer screening. Oncotarget. 2017 May;8(38):64358–64372

8. Cheng F, Yuan Q, Yang J, Wang W, Liu H: The prognostic value of serum neuron-specific enolase in traumatic brain injury: systematic review and meta-analysis. PLoS One. 2014 Sep 4;9(9):e106680

Method Description
Describes how the test is performed and provides a method-specific reference

Neuron-specific enolase (NSE) is measured in this homogeneous automated immunofluorescent assay on the BRAHMS Kryptor. The Kryptor uses TRACE (time resolved amplified cryptate emission) technology based on a nonradioactive transfer of energy. This transfer occurs between 2 fluorescent tracers: the donor (europium cryptate) and the acceptor (XL665). In the NSE assay, 2 monoclonal antibodies are labeled, 1 with europium cryptate and 1 with XL665. NSE is sandwiched between the 2 antibodies, bringing them into close proximity. When the antigen-antibody complex is excited with a nitrogen laser at 337 nm, some fluorescent energy is emitted at 620 nm, and the rest is transferred to XL665. This energy is then emitted as fluorescence at 665 nm. A ratio of the energy emitted at 665 nm to that emitted at 620 nm (internal reference) is calculated for each sample. Signal intensity is proportional to the number of antigen-antibody complexes formed and, therefore, to antigen concentration.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Saturday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 3 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

2 weeks

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Rochester

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

83520

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
NSE Neuron Specific Enolase, S 15060-7
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
NSE Neuron Specific Enolase, S 15060-7

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | PHP Pdf | CMS Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports